Video

freedom to create

The easiest way to fixing stairs and landings

The Architect gains a smooth obstacle-free soffit with no supports on show

The Engineer gains a robust, simple and efficient connection, which can also be used to satisfy robustness

The Insitu Contractor does not need to incorporate connections into the wall requiring tight tolerance

The Precaster keeps control of the connection within the factory, with no need for specialist operations on site

The Main Contractor gains reduced crane hook-time requirements, and rapid provision of access stairs


Advantages with IC stair connectors

Corbel-free connection between staircase and landing.

Sustaiable
Cost effective solution
• Faster and safer installation on site, see stair film “installation”
Reduced crane time
• No welding or bolting on site
Impact sound insulation
ETA approved/CE market product
Design tools / drawings 2D 3D
• Tested for seismic areas
• Invisible


Area of use


References

See link for more references.
 

Guidance to IC Stair Connections

See: Memo 31


What are the requirements for the stairs?

  • Surface, Terrasso, see below
  • Soundreduction, see Memo 47
  • Fire, see side 9 and Memo 45

TSS or RVK

 

TSS – (Terrasso Stair Support).

Inner tubes are pulled out with wire and return rope (no visible marks on the surface, suitable for terrace surfaces).

RVK – (Repos  Vegg Konsollfritt (Repos Wall Consoll free)). 

Inner tubes are pushed out by hand / tools from top of repos (casting visible in surface)


TSS for landing/wall

Artikkel nr Beskrivelse Kapasitet Bilde
TSS 60 p Slim design allows thinner slabs all the waydown to ≥120 mm (full capacity 170 mm). Outer sleeve made of recycled HDPE. 57 kN
TSS 101 Connector capacity up to 80 kN in a minimum 200 mm thick landing increasing to 100 kN for 265 mm thick landing. 100 kN
TSS 102 Incorporates sound reducing rubber composite. Connector capacity up to 80 kN in a minimum 200 mm thick landing increasing to 100 kN for 265 mm thick landing 100 kN

RVK for landing/wall

Artikkel nr Beskrivelse Kapasitet Bilde
RVK 60 p Slim design enables thinner landings and stair thicknesses ≥120mm (full capacity 170mm). Capacity up to 57kN. Recycled HDPE outer. 57 kN
RVK 101 Standard connector capacity up to 80 kN in a minimum 200 mm thick landing, increasing to 100 kN for 265 mm thick landing. 100 kN

IC Box

Artikkel nr Beskrivelse Kapasitet Bilde
IC Box Recess box, out-block .Made of 100% recycled HDPE.
IC Box SRU Recess box with sound reduction Recycled HDPE.

Connections for stair flight to landing.

Artikkel nr Beskrivelse Kapasitet Bilde
TSS 20 FA Stairflight to landing connector with adjustment. 20 kN
TSS 25 L Stair flight to landing connctor with adjustment and lifting device. 25 kN
TSS 60 P Slim design allows thinner slabs all the way down to ≥120 mm (full capacity 170 mm). Outer sleeve made of recycled HDPE. 57 kN

TSS 25 L

  • Lift of element under production.
  • Treads for wire loop lift during installation at site.
  • Stepless height adjustment during installation.
  • Saves stair nosing’s.
  • Efficient installation on construction site, avoids shimming.
  • No need for local reinforcement.

For more information, see memo 65 A.


TSS 20 FA

  • Stepless height adjustment.
  • Saves stair nosing’s..
  • Efficient installation on construction site, avoids shimming.

For more information see: Memo 65 A


TSS 60 P

Can be used as connector stair flight to landing.


Which model and capacity to choose ?

Our bespoken calculation tool helps you to find correct model.

Tip! TSS/RVK should be located as close to the front edge as possible to avoid uplift/negative
forces in the rear end of the element.


Reinforcement of stair connectors TSS/RVK landing-wall

Standardized local reinforcement for TSS/RVK, see Memo 55
See also film «Stairs engineer» at IC akademi


Additional products

For more info see Memo 41

Article nr Description
GF 60 Vertical rubber flange 240x190x5
GF 100 Vertical rubber flange 240x190x5
GF 102 Vertical rubber flange 240x190x5
Lokk 101 Cap for sealing storage and transport RVK101/TSS101
Lokk TSS 102 Cap for sealing storage and transport TSS 102
IC Box 100 SRU IC Box 100 SRU recycled HDPE with sound insulation 170x115x100
IC Box 100 IC Box 100 SRU recycled HDPE 170x115x100
USK 100 Out block RVK/TSS
USK 100 M Out block with magnet RVK/TSS

Fire protection

See Memo 45 and IC Academy for correct installation.

Fire protection is taken care of in a good way when using IC star connectors.
After installation the TSS/RVK will be completely covered with concrete.

Fire rating in accordance with Eurocode

Required fire resistance R30 R60 R90 R120
Minimum cover «C» mm0 0 25 30 60

Impact sound insulation

IC deliver several solutions for impact sound insulation, see Memo 47 and IC Academy film stair
engineer.

TSS102 with vertical rubber flange, reduce sound impact by 22-28 dB

TSS/RVK with IC-Box SRU, reduce impact sound by 8-23 dB

TSS/RVK with vertical rubber flange, reduce sound impact by 10-12 dB


Slab thickness and edge distances

See Memo 55

Drawings
At our webpage click resources and you will find drawings for each model in the most used
formats
https://www.invisibleconnections.no/category/tegninger/#tss-og-rvk

Production
See Memo 20 and 32 for production procedure.
IC Academy fil stair production
https://www.invisibleconnections.no/category/ic-akademiet/

Installation
See IC Academy stair installation
https://www.invisibleconnections.no/category/ic-akademiet/

Approvals
ETA
EN 1090
https://www.invisibleconnections.no/category/godkjenning/


Reinforcement of connector star flight-landing

Reinforcement of connector star flight-landing  TSS 25 L, se Memo 65A

Reinforcement of connector star flight-landing  TSS 20 FA, se Memo 65

TSS25L no need for additional local reinforcement, the backplate and flat steel is enough

Vertical load 25 kN,
Lifting capacity 8 kN


Movie – Stair connections


IC Academy

For more info and films, see IC Academy. Engineering and assembly.


We offer connections for