Standard reinforcement – column

memo-523-figur-1-eng

The figure illustrates the recommended principal reinforcement in the column. A portion of the vertical force will spread into the column via the reinforcement bar welded to the bottom of the steel plate, while the remaining force will go into the column via distributed concrete stress underneath the steel plate.  Splitting forces will occur due to horizontal spreading of the forces into the cross section of the column.