- Hjem
- Products
- Balcony connections
- Connection with shear for sandwich wall
- BWC WB unit used with inner tube with angle
Do you want more information and pricing?
1 / 2
BWC WB unit used with inner tube with angle
- Allows the balcony to be installed at a later stage
- Effective thermal break, reducing heat flow through the connection
- Only local penetrations of the external leaf of the wall element, facilitating effective weatherproofing
- Integrated impact sound reduction using elastomeric elements
- Documented fire resistance
- High load-bearing capacity in a compact solution
- Comprehensive documentation, including ETA, EPD and BIM objects
The system consists of several components:
BWC
WB:
The
BWC WB is cast into the precast wall element at the manufacturing
plant and is installed flush with the external leaf of the wall
panel.
Inner
tube:
The
inner tube is the component that connects the building structure to
the balcony or access balcony element. It is available in several
versions. The most common version is used in combination with a
cast-in BWC
55-4 balcony box
or supplied with a welded angle bracket.
Angle
bracket:
The
inner tube is supplied with a welded angle bracket and a steel
dowel
for supporting the balcony or access balcony element. The size of the
angle bracket and the X-dimension
are adapted to the specific project in cooperation with the
structural engineer.
Function and Construction
All components are manufactured from S355 structural steel and are hot-dip galvanised.
Impact Sound Reduction and Thermal Break
Two integrated elastomeric elements between the inner and outer tubes reduce the transmission of impact and structure-borne sound through the balcony support connection. This contributes to good acoustic performance in the completed structure.
A thermal bridge is a part of the building envelope through which heat is transferred more readily than through the surrounding construction. Minimising thermal bridges is therefore important in energy-efficient buildings.
The integrated elastomeric elements provide a thermal break between the inner and outer tubes, reducing heat transfer through the connection.
Applications
The system can be adapted to a wide range of construction methods, including cast-in-situ concrete slabs, filigree slabs, hollow-core slabs and cross-laminated timber (CLT) floors.
In combination with our stair connection system, the solution can also be used where balconies are recessed into the building.
The system can also be adapted for refurbishment and conversion projects, for example where existing office buildings are converted into residential buildings and new balconies are required.
Fire Resistance
The solution can be supplied for fire resistance classes R30, R60 and R90, depending on the required fire resistance and the specified intumescent coating system.
Dokumentasjon og prosjektering
Teknisk dokumentasjon, EPD og BIM-objekter legger til rette for effektiv prosjektering, dokumentasjon og digital samhandling gjennom hele byggeprosjektet.
EPD-en gir tredjepartsverifisert dokumentasjon av produktets miljøpåvirkning gjennom livsløpet og kan benyttes som underlag for prosjektets bærekrafts- og miljømål.
Den europeiske tekniske vurderingen, ETA, dokumenterer produktets ytelse og egnethet for bruk i prefabrikkerte betongkonstruksjoner. CE-merket produksjon i henhold til EN 1090 ivaretar sporbarhet, produksjonskontroll og dokumentert kvalitet i samsvar med gjeldende europeiske krav.
- Vertical load capacity, ULS: Fv
- 55 kN
- Horizontal load capacity, ULS: FH
- 20 kN
- Balcony thickness
- 100-250 mm
- Fire resistance with 25 mm concrete cover – R-
- R60
- Impact sound pressure level achieved down to (dead load Gk): L′n,w
- 48 dB
- Outer tube weight
- 18 kg
- Inner tube weight
- 15 kg
- Inner tube width
- 100 mm
- Inner tube height
- 50 mm
- Inner tube thickness
- 6 mm
- Outer tube width
- 120 mm
- Outer tube height
- 440-560 mm
- Anchorage reinforcement. Steel grades B500NA, B500NB, B500NC may be used
- Ø12 mm
- Reinforcement stirrups shall bear against
- SHS/half-round steel bar
- Minimum concrete grade
- C35/45
BWC WB tegning
BWC 55 light innerrør 2 V tegning kort for WB