1 / 2

BWC WB and TSS unit

USP:

  • Allows the balcony to be installed at a later stage
  • Effective thermal break, reducing heat flow through the connection
  • Only local penetrations of the external leaf of the wall element, facilitating effective weatherproofing
  • Integrated impact sound reduction using elastomeric elements
  • Documented fire resistance
  • High load-bearing capacity in a compact solution
  • Comprehensive documentation, including ETA, EPD and BIM objects

The system consists of several components:

BWC WB:
The BWC WB is cast into the precast wall element at the manufacturing plant and is installed flush with the external leaf of the wall panel.

Inner tube:
The inner tube is the component that connects the building structure to the balcony or access balcony element. It is available in several versions. The most common version is used in combination with a cast-in BWC 55-4 balcony box or supplied with a welded angle bracket.

TSS 102 G:
The TSS 102 G is recommended for use in the precast balcony element.

Function and Construction

All components are manufactured from S355 structural steel and are hot-dip galvanised.

Impact Sound Reduction and Thermal Break

Two integrated elastomeric elements between the inner and outer tubes reduce the transmission of impact and structure-borne sound through the balcony support connection. This contributes to good acoustic performance in the completed structure.

A thermal bridge is a part of the building envelope through which heat is transferred more readily than through the surrounding construction. Minimising thermal bridges is therefore important in energy-efficient buildings.

The integrated elastomeric elements provide a thermal break between the inner and outer tubes, reducing heat transfer through the connection.

Applications

The system can be adapted to a wide range of construction methods, including cast-in-situ concrete slabs, filigree slabs, hollow-core slabs and cross-laminated timber (CLT) floors.

In combination with our stair connection system, the solution can also be used where balconies are recessed into the building.

The system can also be adapted for refurbishment and conversion projects, for example where existing office buildings are converted into residential buildings and new balconies are required.

Fire Resistance

When cast into concrete, the load-bearing steel components are protected against elevated temperatures by the surrounding concrete cover.

The solution can be designed for fire resistance classes R30, R60, R90 and R120, depending on the specified concrete cover.

Documentation and Design

Technical documentation, EPD and BIM objects facilitate efficient structural design, documentation and digital collaboration throughout the construction project.

The EPD provides third-party verified documentation of the product's environmental impact throughout its life cycle and can be used as supporting documentation for the project's sustainability and environmental objectives.

The European Technical Assessment (ETA) documents the product's performance and fitness for its intended use in precast concrete structures. CE-marked production in accordance with EN 1090 ensures traceability, factory production control and documented quality in accordance with applicable European requirements.

Vertical load capacity, ULS: Fv
55 kN
Horizontal load capacity, ULS: FH
0 kN
Balcony thickness
200-250 mm
Fire resistance with 25 mm concrete cover – R-
R60
Impact sound pressure level achieved down to (dead load Gk): L′n,w
48 dB
Outer tube weight
18 kg
Inner tube weight
11 kg
Inner tube length
402 mm
Inner tube width
100 mm
Inner tube height
50 mm
Inner tube thickness
6 mm
Outer tube width
150 mm
Outer tube height
440-560 mm
Anchorage reinforcement. Steel grades B500NA, B500NB, B500NC may be used
Ø12 mm
Reinforcement stirrups shall bear against
SHS/half-round steel bar
Minimum concrete grade
C35/45

  • BWC WB tegning
    BWC WB tegning
  • BWC 55 light innerrør 2 kort for WB
    BWC 55 light innerrør 2 kort for WB